British Standard 75 Ohm telecommunication cables, specially designed for digital telephone exchange and interconnection of telecommunication equipment, in a range of telecommunication systems. These cables are available in LSOH and PVC versions, in single or multi-core versions, to suit a range of applications and requirements.
Key Benefits
|
Applications
|
BT3002- single core | 0.31mm BC conductor , 90% Double TC Braid , 3.55mm PVC Jacket, Standard Shield | 1-200 | BNC, SMB, 1.0/2.3 PLUG ,43/5FQT ,1.6/5.6 MALE CRIMP | |
BT3002- 8 core | 0.31mm BC conductor , 90% Double TC Braid , 3.55mm PVC Jacket, 16.05mm Overall PVC Jacket | 1-200 | BNC, SMB, 1.0/2.3 PLUG ,43/5FQT ,1.6/5.6 MALE CRIMP | |
BT3002- 16 core | 0.31mm BC conductor , 90% Double TC Braid , 3.55mm PVC Jacket, 19.60mm Overall PVC Jacket | 1-200 | BNC, SMB, 1.0/2.3 PLUG ,43/5FQT ,1.6/5.6 MALE CRIMP | |
BT2003- single core | 0.61mm BC conductor , 90% Double TC Braid , 6.65mm PVC Jacket, Standard Shield | 1-100 | BNC CRIMP, 1.0/2.3 PLUG , 1.6/5.6 CRIMP , | |
BT2002- single core | 7*0.20mm BC conductor , 90% Double TC Braid , 5.10mm PVC Jacket, Standard Shield | 1-200 | BNC CRIMP ,SMZ, BMA |
BT3002
Attenuation (@20 ℃)
Frequency(MHz) | Max Attenuation (dB/100ft) | Max Attenuation (dB/100m) |
1 | 0.7 | 2.3 |
4 | 1.4 | 4.5 |
5 | 1.5 | 4.8 |
17 | 2.8 | 9.2 |
70 | 5.7 | 18.7 |
100 | 6.9 | 22.5 |
200 | 9.8 | 32.0 |
BT2003
Attenuation (@20 ℃)
Frequency(MHz) | Max Attenuation (dB/100ft) | Max Attenuation (dB/100m) |
1 | 0.31 | 1.00 |
2 | 0.45 | 1.45 |
5 | 0.74 | 2.40 |
10 | 1.01 | 3.30 |
20 | 1.45 | 4.75 |
50 | 2.32 | 7.60 |
100 | 3.33 | 10.90 |
BT 2002
Attenuation (@20 ℃)
Frequency(MHz) | Max Attenuation (dB/100ft) | Max Attenuation (dB/100m) |
1 | 0.39 | 1.26 |
2 | 0.57 | 1.85 |
5 | 0.92 | 3.00 |
10 | 1.28 | 4.20 |
20 | 1.85 | 6.05 |
50 | 2.93 | 9.60 |
100 | 4.21 | 13.80 |